Assessment Year | 1993 |
---|---|
Principal Product | Canoes |
NAICS |
n/a
|
SIC | 3732: Boat Building and Repairing |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
100,000
ft2
|
Annual Production | 29,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,149 | 1,080,598 |
kWh
|
$0.11 |
Fuel Oil #2 | $79,252 | 17,893 |
MMBtu
|
$4.43 |
Fuel Oil #6 | $28,737 | 13,247 |
MMBtu
|
$2.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,312 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,466 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,631 | $1,344 |
$2,631
25,791
kWh
|
- | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $14,846 | $22,500 | - |
$14,846
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $579 | $1,405 |
$579
5,569
kWh
|
- | |
04 | 2.1211: Move boiler to more efficient location | $256 | $200 |
$256
1,758
kWh
|
- | |
TOTAL RECOMMENDED | $18,312 | $25,449 |
$3,466
33,118
kWh
|
$14,846
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,466 | $2,949 |
$3,466
33,118
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs