Assessment Year | 2011 |
---|---|
Principal Product | Soup |
NAICS | 311991: Perishable Prepared Food Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 160 |
Plant Area |
70,000
ft2
|
Annual Production | 32,500,000
lb
|
Production Hrs. Annual | 5,590
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $354,145 | 3,656,592 |
kWh
|
$0.097 |
Electricity Demand | $200,568 | 9,230 |
kW-mo/yr
|
$21.73 |
Electricity Fees | $45,492 | - |
|
- |
Natural Gas | $368,022 | 34,596 |
MMBtu
|
$10.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $72,806 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2611: Moderate cooling tower outlet temperature | $47,869 | $10,650 |
$32,310
333,781
kWh
|
$15,559
-
kW-mo/yr
|
- | |
02 | 2.4131: Size electric motors for peak operating efficiency | $15,371 | $17,325 |
$9,548
98,646
kWh
|
$5,823
-
kW-mo/yr
|
- | |
03 | 2.2136: Install / repair insulation on steam lines | $4,256 | $8,190 | - | - |
$4,256
-
MMBtu
|
|
04 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $2,288 | $2,070 |
$1,600
16,524
kWh
|
$688
-
kW-mo/yr
|
- | |
05 | 2.2694: Use highest temperature for chilling or cold storage | $2,033 | $200 |
$1,425
14,722
kWh
|
$608
-
kW-mo/yr
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $496 | $700 |
$496
5,132
kWh
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $493 | $200 |
$493
5,090
kWh
|
- | - | |
TOTAL RECOMMENDED | $72,806 | $39,335 |
$45,872
473,895
kWh
|
$22,678
-
kW-mo/yr
|
$4,256
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs