Assessment Year | 2023 |
---|---|
Principal Product | Water |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $5 M to 10M |
# of Employees | 3 |
Plant Area |
10,000
ft2
|
Annual Production | 1,460,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $206,478 | 1,822,724 |
kWh
|
$0.11 |
Electricity Demand | $70,203 | 3,800 |
kW-mo/yr
|
$18.47 |
Electricity Fees | $9,120 | - |
|
- |
LPG | $2,917 | 204 |
MMBtu
|
$14.30 |
TOTAL YEARLY COSTS | $288,718 | |||
RECOMMENDED SAVINGS* | $880,034 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $786,360 | $8,384,740 |
$429,193
3,798,169
kWh
|
$33,829
-
kW-mo/yr
|
$323,338 | - | |
02 | 2.7273: Install desiccant humidity control system | $53,317 | $27,882 |
$(-5,464.0)
(-48,355)
kWh
|
$(-1,219.0)
-
kW-mo/yr
|
- | $60,000 | |
03 | 2.7234: Use heat pump for space conditioning | $22,535 | $8,016 |
$18,415
162,965
kWh
|
$4,120
-
kW-mo/yr
|
- | - | |
04 | 2.7234: Use heat pump for space conditioning | $9,331 | $2,100 |
$5,562
49,224
kWh
|
$3,769
-
kW-mo/yr
|
- | - | |
05 | 2.7234: Use heat pump for space conditioning | $8,491 | $10,020 |
$5,165
45,708
kWh
|
$3,326
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $880,034 | $8,432,758 |
$452,871
4,007,711
kWh
|
$43,825
-
kW-mo/yr
|
$323,338 | $60,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs