Assessment Year | 2022 |
---|---|
Principal Product | Roller Chains |
NAICS | 333613: Mechanical Power Transmission Equipment Manufacturing |
SIC | 3568: Mechanical Power Transmission Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 175 |
Plant Area |
209,100
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $526,026 | 5,705,760 |
kWh
|
$0.092 | |
Electricity Demand | $81,464 | 11,825 |
kW-mo/yr
|
$6.89 | |
Electricity Fees | $3,765 | - |
|
- | |
Natural Gas | $514,325 | 61,679 |
MMBtu
|
$8.34 | |
Waste Disposal Costs | |||||
Water Usage | $6,143 | 1,259 |
Tgal
|
$4.88 | |
Water Disposal | $8,371 | 1,259 |
Tgal
|
$6.65 | |
TOTAL YEARLY COSTS | $1,140,094 | ||||
RECOMMENDED SAVINGS* | $178,093 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $37,422 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $108,785 | $906,122 |
$103,584
1,125,905
kWh
|
$5,201
-
kW-mo/yr
|
- | |
02 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $26,668 | $60,000 | - | - |
$26,668
-
MMBtu
|
|
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $13,709 | $182,139 |
$18,560
201,743
kWh
|
$1,904
-
kW-mo/yr
|
$(-6,755.0)
-
MMBtu
|
|
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $10,754 | $14,292 |
$10,754
116,891
kWh
|
- | - | |
05 | 2.6122: Adjust vents to minimize energy use | $8,349 | $10,667 |
$8,349
90,750
kWh
|
- | - | |
06 | 2.2511: Insulate bare equipment | $6,066 | $2,910 |
$5,501
59,792
kWh
|
$565
-
kW-mo/yr
|
- | |
07 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,762 | $505 |
$3,411
37,081
kWh
|
$351
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $178,093 | $1,176,635 |
$150,159
1,632,162
kWh
|
$8,021
-
kW-mo/yr
|
$19,913
-
MMBtu
|
||
TOTAL IMPLEMENTED | $37,422 | $74,292 |
$10,754
116,891
kWh
|
- |
$26,668
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs