Assessment Year 2022
Principal Product Roller Chains
NAICS 333613: Mechanical Power Transmission Equipment Manufacturing
SIC 3568: Mechanical Power Transmission Equipment, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 175
Plant Area 209,100
ft2
Annual Production 4,000,000
lb
Production Hrs. Annual 8,760
hrs
Location (State) Massachusetts

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $526,026 5,705,760
kWh
Electricity Demand $81,464 11,825
kW-mo/yr
Electricity Fees $3,765 -
Natural Gas $514,325 61,679
MMBtu
Waste Disposal Costs
Water Usage $6,143 1,259
Tgal
Water Disposal $8,371 1,259
Tgal
TOTAL YEARLY COSTS $1,140,094
RECOMMENDED SAVINGS* $178,093 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $37,422

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.9114: Use solar heat to make electricty $108,785 $906,122 $103,584
1,125,905
kWh
$5,201
-
kW-mo/yr
-
02 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $26,668 $60,000 - - $26,668
-
MMBtu
03 2.1311: Replace electrically-operated equipment with fossil fuel equipment $13,709 $182,139 $18,560
201,743
kWh
$1,904
-
kW-mo/yr
$(-6,755.0)
-
MMBtu
04 2.6212: Turn off equipment during breaks, reduce operating time $10,754 $14,292 $10,754
116,891
kWh
- -
05 2.6122: Adjust vents to minimize energy use $8,349 $10,667 $8,349
90,750
kWh
- -
06 2.2511: Insulate bare equipment $6,066 $2,910 $5,501
59,792
kWh
$565
-
kW-mo/yr
-
07 2.6212: Turn off equipment during breaks, reduce operating time $3,762 $505 $3,411
37,081
kWh
$351
-
kW-mo/yr
-
TOTAL RECOMMENDED $178,093 $1,176,635 $150,159
1,632,162
kWh
$8,021
-
kW-mo/yr
$19,913
-
MMBtu
TOTAL IMPLEMENTED $37,422 $74,292 $10,754
116,891
kWh
- $26,668
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs