Assessment Year | 2022 |
---|---|
Principal Product | Contact lens blanks |
NAICS | 339115: Ophthalmic Goods Manufacturing |
SIC | 3851: Ophthalmic Goods |
Sales Range | $10 M to 50M |
# of Employees | 34 |
Plant Area |
33,000
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 4,271
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $125,029 | 1,154,060 |
kWh
|
$0.11 | |
Electricity Demand | $28,185 | 3,394 |
kW-mo/yr
|
$8.30 | |
Electricity Fees | $198 | - |
|
- | |
Natural Gas | $26,013 | 2,231 |
MMBtu
|
$11.66 | |
Waste Disposal Costs | |||||
Water Usage | $1,441 | 99 |
Tgal
|
$14.58 | |
Water Disposal | $1,441 | 99 |
Tgal
|
$14.58 | |
TOTAL YEARLY COSTS | $182,307 | ||||
RECOMMENDED SAVINGS* | $37,548 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $3,815 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $21,194 | $381,355 |
$17,806
164,874
kWh
|
$3,388
-
kW-mo/yr
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,849 | $2,575 |
$1,946
18,018
kWh
|
$6,903
-
kW-mo/yr
|
- | - | |
03 | 2.2437: Recover waste heat from equipment | $2,180 | $699 | - | - |
$2,180
-
MMBtu
|
- | |
04 | 2.7224: Reduce space conditioning during non-working hours | $1,247 | $2,731 |
$69
635
kWh
|
- |
$1,178
-
MMBtu
|
- | |
05 | 2.8121: Apply for tax-free status for energy purchases | $1,635 | $1,000 | - | - | - | $1,635 | |
06 | 2.2511: Insulate bare equipment | $1,204 | $706 |
$1,204
11,152
kWh
|
- | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,239 | $3,220 |
$1,123
10,400
kWh
|
$116
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $37,548 | $392,286 |
$22,148
205,079
kWh
|
$10,407
-
kW-mo/yr
|
$3,358
-
MMBtu
|
$1,635 | ||
TOTAL IMPLEMENTED | $3,815 | $1,699 | - | - |
$2,180
-
MMBtu
|
$1,635 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs