Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $777,034 | 7,679,150 |
kWh
|
$0.10 |
Electricity Demand | $102,332 | 13,644 |
kW-mo/yr
|
$7.50 |
Electricity Fees | $923 | - |
|
- |
LPG | $59,246 | 2,957 |
MMBtu
|
$20.04 |
TOTAL YEARLY COSTS | $939,535 | |||
RECOMMENDED SAVINGS* | $59,466 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,185 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $34,736 | $24,400 |
$31,406
310,951
kWh
|
$3,330
-
kW-mo/yr
|
- | - | |
02 | 2.2511: Insulate bare equipment | $6,782 | $8,620 |
$6,782
67,148
kWh
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,700 | $4,400 |
$6,700
66,340
kWh
|
- | - | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $3,485 | $1,000 | - | - | - | $3,485 | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,278 | $15,850 |
$3,278
32,455
kWh
|
- | - | - | |
06 | 2.2691: Shut off cooling if cold outside air will cool process | $2,891 | $4,445 | - | - |
$2,891
-
MMBtu
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $1,594 | $5,100 |
$1,594
15,785
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $59,466 | $63,815 |
$49,760
492,679
kWh
|
$3,330
-
kW-mo/yr
|
$2,891
-
MMBtu
|
$3,485 | ||
TOTAL IMPLEMENTED | $11,185 | $13,945 |
$8,294
82,125
kWh
|
- |
$2,891
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Administrative Changes Savings |