ITAC Assessment: MA0829
ITAC logo
ITAC Assessment: MA0829
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product plastic bags
NAICS 326111: Plastics Bag and Pouch Manufacturing
SIC 2673: Plastics, Foil, and Coated Paper Bags
Sales Range $10
M
to 50
M
# of Employees 88
Plant Area 118,000
ft2
Annual Production 30,000,000
lb
Production Hrs. Annual 8,400
hrs
Location (State) Massachusetts

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $777,034 7,679,150
kWh
Electricity Demand $102,332 13,644
kW-mo/yr
Electricity Fees $923 -
LPG $59,246 2,957
MMBtu
TOTAL YEARLY COSTS $939,535
RECOMMENDED SAVINGS* $59,466 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,185

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings Administrative Changes Savings
01 2.2614: Use cooling tower or economizer to replace chiller cooling $34,736 $24,400 $31,406
310,951
kWh
$3,330
-
kW-mo/yr
- -
02 2.2511: Insulate bare equipment $6,782 $8,620 $6,782
67,148
kWh
- - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $6,700 $4,400 $6,700
66,340
kWh
- - -
04 2.8121: Apply for tax-free status for energy purchases $3,485 $1,000 - - - $3,485
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,278 $15,850 $3,278
32,455
kWh
- - -
06 2.2691: Shut off cooling if cold outside air will cool process $2,891 $4,445 - - $2,891
-
MMBtu
-
07 2.4133: Use most efficient type of electric motors $1,594 $5,100 $1,594
15,785
kWh
- - -
TOTAL RECOMMENDED $59,466 $63,815 $49,760
492,679
kWh
$3,330
-
kW-mo/yr
$2,891
-
MMBtu
$3,485
TOTAL IMPLEMENTED $11,185 $13,945 $8,294
82,125
kWh
- $2,891
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs