Assessment Year | 2021 |
---|---|
Principal Product | Printed circuit boards |
NAICS | 334412: Bare Printed Circuit Board Manufacturing |
SIC | 3672: Printed Circuit Boards |
Sales Range | $1 M to 5M |
# of Employees | 20 |
Plant Area |
27,000
ft2
|
Annual Production | 50,400
lb
|
Production Hrs. Annual | 2,185
hrs
|
Location (State) | New Hampshire |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $121,861 | 1,078,800 |
kWh
|
$0.11 | |
Electricity Demand | $70,282 | 5,294 |
kW-mo/yr
|
$13.28 | |
Electricity Fees | $5,151 | - |
|
- | |
Natural Gas | $5,490 | 377 |
MMBtu
|
$14.56 | |
Waste Disposal Costs | |||||
Water Usage | $25,861 | 3,866 |
Tgal
|
$6.69 | |
Water Disposal | $17,229 | 3,866 |
Tgal
|
$4.46 | |
TOTAL YEARLY COSTS | $245,873 | ||||
RECOMMENDED SAVINGS* | $37,374 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $1,530 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.3122: Use filtration, centrifuging to remove contaminants | $27,883 | $250,000 |
$(-2,725.0)
(-24,119)
kWh
|
$(-996.0)
-
kW-mo/yr
|
$24,774
-
Tgal
|
$6,830 | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,639 | $14,650 |
$4,639
41,053
kWh
|
- | - | - | |
03 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $2,447 | $10,800 |
$1,332
11,791
kWh
|
$1,115
-
kW-mo/yr
|
- | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $979 | $1,631 |
$979
8,664
kWh
|
- | - | - | |
05 | 2.6218: Turn off equipment when not in use | $552 | $250 |
$552
4,881
kWh
|
- | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $551 | $1,450 |
$551
4,877
kWh
|
- | - | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $323 | $625 |
$323
2,859
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $37,374 | $279,406 |
$5,651
50,006
kWh
|
$119
-
kW-mo/yr
|
$24,774
-
Tgal
|
$6,830 | ||
TOTAL IMPLEMENTED | $1,530 | $3,081 |
$1,530
13,541
kWh
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs