Assessment Year | 2020 |
---|---|
Principal Product | Treated potable water |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $5 M to 10M |
# of Employees | 22 |
Plant Area |
26,436
ft2
|
Annual Production | 1,102,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $71,622 | 542,400 |
kWh
|
$0.13 |
Electricity Demand | $10,766 | 1,805 |
kW-mo/yr
|
$5.96 |
Electricity Fees | $2,676 | - |
|
- |
LPG | $70,313 | 4,794 |
MMBtu
|
$14.67 |
TOTAL YEARLY COSTS | $155,377 | |||
RECOMMENDED SAVINGS* | $150,968 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,271 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $90,005 | $373,605 |
$57,422
435,017
kWh
|
$1,575
-
kW-mo/yr
|
- | $31,008 | |
02 | 2.3322: Use existing dam to generate electricity | $33,419 | $150,000 |
$32,059
242,869
kWh
|
$1,360
-
kW-mo/yr
|
- | - | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $11,675 | $375 | - | - |
$11,675
-
MMBtu
|
- | |
04 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $8,358 | $250 |
$188
1,424
kWh
|
- |
$8,170
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,596 | $24,389 |
$4,898
37,105
kWh
|
$698
-
kW-mo/yr
|
- | - | |
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,915 | $250 | - |
$1,915
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $150,968 | $548,869 |
$94,567
716,415
kWh
|
$5,548
-
kW-mo/yr
|
$19,845
-
MMBtu
|
$31,008 | ||
TOTAL IMPLEMENTED | $17,271 | $24,764 |
$4,898
37,105
kWh
|
$698
-
kW-mo/yr
|
$11,675
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs