Assessment Year | 2020 |
---|---|
Principal Product | Surgical and Medical Instruments |
NAICS | 339112: Surgical and Medical Instrument Manufacturing |
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $50 M to 100M |
# of Employees | 474 |
Plant Area |
690,000
ft2
|
Annual Production | 505,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $587,425 | 4,450,755 |
kWh
|
$0.13 | |
Electricity Demand | $45,419 | 8,764 |
kW-mo/yr
|
$5.18 | |
Electricity Fees | $2,676 | - |
|
- | |
Natural Gas | $209,539 | 16,125 |
MMBtu
|
$12.99 | |
Waste Disposal Costs | |||||
Water Usage | $27,354 | 3,068 |
Tgal
|
$8.92 | |
Water Disposal | $41,268 | 2,168 |
Tgal
|
$19.04 | |
TOTAL YEARLY COSTS | $913,681 | ||||
RECOMMENDED SAVINGS* | $358,845 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $64,579 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $228,815 | $892,794 |
$228,815
1,495,520
kWh
|
- | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $56,847 | $3,250 |
$4,737
30,964
kWh
|
$52,110
-
MMBtu
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $35,615 | $32,940 |
$35,615
232,780
kWh
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,190 | $5,960 |
$17,190
112,353
kWh
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,774 | $16,650 |
$11,774
76,952
kWh
|
- | |
06 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $8,604 | $500 |
$274
1,791
kWh
|
$8,330
-
MMBtu
|
|
TOTAL RECOMMENDED | $358,845 | $952,094 |
$298,405
1,950,360
kWh
|
$60,440
-
MMBtu
|
||
TOTAL IMPLEMENTED | $64,579 | $55,550 |
$64,579
422,085
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs