Assessment Year | 2019 |
---|---|
Principal Product | Water |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $1 M to 5M |
# of Employees | 5 |
Plant Area |
40,000
ft2
|
Annual Production | 365,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $65,736 | 701,342 |
kWh
|
$0.094 |
Electricity Demand | $26,605 | 1,442 |
kW-mo/yr
|
$18.45 |
Electricity Fees | $4,766 | - |
|
- |
LPG | $7,930 | 365 |
MMBtu
|
$21.73 |
TOTAL YEARLY COSTS | $105,037 | |||
RECOMMENDED SAVINGS* | $18,470 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,232 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $4,315 | $14,350 |
$14,928
158,805
kWh
|
$4,096
-
kW-mo/yr
|
$(-14,709.0)
-
MMBtu
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,245 | $6,660 |
$3,758
39,980
kWh
|
$3,487
-
kW-mo/yr
|
- | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $3,193 | $200 |
$1,846
19,636
kWh
|
- |
$1,347
-
MMBtu
|
|
04 | 3.1191: Change procedures / equipment / operating conditions | $1,678 | $300 |
$1,678
17,852
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,405 | $2,499 |
$704
7,486
kWh
|
$701
-
kW-mo/yr
|
- | |
06 | 2.7221: Lower temperature during the winter season and vice-versa | $634 | $200 |
$634
6,741
kWh
|
- | - | |
TOTAL RECOMMENDED | $18,470 | $24,209 |
$23,548
250,500
kWh
|
$8,284
-
kW-mo/yr
|
$(-13,362.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,232 | $2,899 |
$3,184
33,863
kWh
|
$701
-
kW-mo/yr
|
$1,347
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs