Assessment Year | 2018 |
---|---|
Principal Product | Thermoformed Plastic Packaging |
NAICS | 326112: Plastics Packaging Film and Sheet (including Laminated) Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
80,000
ft2
|
Annual Production | 36,000,000
lb
|
Production Hrs. Annual | 6,096
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $694,041 | 5,399,600 |
kWh
|
$0.13 |
Electricity Demand | $66,770 | 11,592 |
kW-mo/yr
|
$5.76 |
Electricity Fees | $35,349 | - |
|
- |
Natural Gas | $8,524 | 583 |
MMBtu
|
$14.63 |
TOTAL YEARLY COSTS | $804,684 | |||
RECOMMENDED SAVINGS* | $115,490 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $687 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $100,737 | $184,800 |
$157,272
1,219,164
kWh
|
$19,561
-
kW-mo/yr
|
$(-76,096.0)
-
MMBtu
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,287 | $200 |
$7,287
56,489
kWh
|
- | - | |
03 | 2.2511: Insulate bare equipment | $6,779 | $911 |
$6,779
52,739
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $687 | $2,512 |
$555
4,306
kWh
|
$132
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $115,490 | $188,423 |
$171,893
1,332,698
kWh
|
$19,693
-
kW-mo/yr
|
$(-76,096.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $687 | $2,512 |
$555
4,306
kWh
|
$132
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs