Assessment Year | 2018 |
---|---|
Principal Product | Soup |
NAICS | 311412: Frozen Specialty Food Manufacturing |
SIC | 2038: Frozen Specialties, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 110 |
Plant Area |
110,000
ft2
|
Annual Production | 2,027
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,231,502 | 9,113,000 |
kWh
|
$0.14 |
Electricity Demand | $99,219 | 18,096 |
kW-mo/yr
|
$5.48 |
Natural Gas | $912,567 | 64,000 |
MMBtu
|
$14.26 |
TOTAL YEARLY COSTS | $2,243,288 | |||
RECOMMENDED SAVINGS* | $192,785 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $149,880 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2621: Modify refrigeration system to operate at a lower pressure | $98,644 | $110,000 |
$98,644
730,696
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $43,627 | $17,006 |
$41,330
306,144
kWh
|
$2,297
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $31,698 | $116,889 |
$31,698
234,802
kWh
|
- | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,164 | $6,660 |
$7,164
53,070
kWh
|
- | - | |
05 | 2.2511: Insulate bare equipment | $4,116 | $10,462 |
$4,116
30,493
kWh
|
- | - | |
06 | 2.2136: Install / repair insulation on steam lines | $3,493 | $1,750 | - | - |
$3,493
-
MMBtu
|
|
07 | 2.7226: Use computer programs to optimize hvac performance | $4,043 | $18,200 |
$4,043
29,945
kWh
|
- | - | |
TOTAL RECOMMENDED | $192,785 | $280,967 |
$186,995
1,385,150
kWh
|
$2,297
-
kW-mo/yr
|
$3,493
-
MMBtu
|
||
TOTAL IMPLEMENTED | $149,880 | $139,218 |
$144,090
1,067,333
kWh
|
$2,297
-
kW-mo/yr
|
$3,493
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs