ITAC Assessment: MA0787
ITAC logo
ITAC Assessment: MA0787
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Steering columns
NAICS 336330: Motor Vehicle Steering and Suspension Components (except Spring) Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $50
M
to 100
M
# of Employees 328
Plant Area 165,000
ft2
Annual Production 5,000,000
pieces
Production Hrs. Annual 8,400
hrs
Location (State) Vermont

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $593,347 6,875,694
kWh
Electricity Demand $349,779 28,640
kW-mo/yr
Electricity Fees $(-69,646.0) -
LPG $131,211 7,991
MMBtu
TOTAL YEARLY COSTS $1,004,691
RECOMMENDED SAVINGS* $92,878 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,156

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.9113: Use solar heat for heat $76,722 $790,840 $51,992
541,581
kWh
$24,730
-
kW-mo/yr
02 2.6212: Turn off equipment during breaks, reduce operating time $6,589 $100 $6,589
76,616
kWh
-
03 2.6212: Turn off equipment during breaks, reduce operating time $4,796 $100 $4,796
65,700
kWh
-
04 2.6212: Turn off equipment during breaks, reduce operating time $4,111 $100 $4,111
47,799
kWh
-
05 2.6212: Turn off equipment during breaks, reduce operating time $660 $100 $660
7,640
kWh
-
TOTAL RECOMMENDED $92,878 $791,240 $68,148
739,336
kWh
$24,730
-
kW-mo/yr
TOTAL IMPLEMENTED $16,156 $400 $16,156
197,755
kWh
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs