Assessment Year | 2017 |
---|---|
Principal Product | metal stampings |
NAICS | 332994: Small Arms, Ordnance, and Ordnance Accessories Manufacturing |
SIC | 3484: Small Arms |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
27,500
ft2
|
Annual Production | 14,600
units
|
Production Hrs. Annual | 7,904
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $124,236 | 1,320,300 |
kWh
|
$0.094 |
Electricity Demand | $34,800 | 3,071 |
kW-mo/yr
|
$11.33 |
Electricity Fees | $21,996 | - |
|
- |
LPG | $1,988 | 81 |
MMBtu
|
$24.60 |
TOTAL YEARLY COSTS | $183,020 | |||
RECOMMENDED SAVINGS* | $67,232 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.9113: Use solar heat for heat | $66,074 | $629,413 |
$66,074
702,914
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $583 | $100 |
$583
6,200
kWh
|
|
03 | 2.2515: Use optimum thickness insulation | $575 | $865 |
$575
6,120
kWh
|
|
TOTAL RECOMMENDED | $67,232 | $630,378 |
$67,232
715,234
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs