Assessment Year | 2017 |
---|---|
Principal Product | Actuators |
NAICS | 333314: Optical Instrument and Lens Manufacturing |
SIC | 3827: Optical Instruments and Lenses |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
70,000
ft2
|
Annual Production | 12
units
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $103,799 | 1,389,900 |
kWh
|
$0.075 | |
Electricity Demand | $44,160 | 2,881 |
kW-mo/yr
|
$15.33 | |
Electricity Fees | $900 | - |
|
- | |
Natural Gas | $19,270 | 1,636 |
MMBtu
|
$11.78 | |
Waste Disposal Costs | |||||
Water Usage | $5,305 | 1,126,940 |
Tgal
|
$0.005 | |
TOTAL YEARLY COSTS | $173,434 | ||||
RECOMMENDED SAVINGS* | $13,231 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $1,933 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $8,661 | $1,503 |
$2,344
31,377
kWh
|
- |
$6,317
-
MMBtu
|
|
02 | 2.7229: Air condition only space necessary | $2,351 | $1,000 |
$206
2,754
kWh
|
- |
$2,145
-
MMBtu
|
|
03 | 2.3212: Optimize plant power factor | $1,809 | $2,784 | - |
$1,809
-
kW-mo/yr
|
- | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $286 | $20 |
$286
3,823
kWh
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $124 | $100 |
$124
1,650
kWh
|
- | - | |
TOTAL RECOMMENDED | $13,231 | $5,407 |
$2,960
39,604
kWh
|
$1,809
-
kW-mo/yr
|
$8,462
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,933 | $2,884 |
$124
1,650
kWh
|
$1,809
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs