| Assessment Year | 2016 |
|---|---|
| Principal Product | Thermoform plastic parts |
| NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 78 |
| Plant Area |
60,000
ft2
|
| Annual Production | 1,500,000
lb
|
| Production Hrs. Annual | 4,335
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $141,315 | 1,118,800 |
kWh
|
$0.13 | |
| Electricity Demand | $16,691 | 4,258 |
kW-mo/yr
|
$3.92 | |
| Natural Gas | $17,099 | 1,511 |
MMBtu
|
$11.32 | |
| Waste Disposal Costs | |||||
| Water Usage | $5,200 | 40,392 |
Tgal
|
$0.13 | |
| TOTAL YEARLY COSTS | $180,305 | ||||
| RECOMMENDED SAVINGS* | $18,029 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $6,803 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $11,226 | $14,820 |
$6,030
47,855
kWh
|
$5,196
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,476 | $6,333 |
$4,476
35,460
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,502 | $3,367 |
$1,502
11,922
kWh
|
- | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $825 | $6,402 |
$825
6,546
kWh
|
- | |
| TOTAL RECOMMENDED | $18,029 | $30,922 |
$12,833
101,783
kWh
|
$5,196
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,803 | $16,102 |
$6,803
53,928
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs