Assessment Year | 2016 |
---|---|
Principal Product | Chemicals for personal care industry |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 61 |
Plant Area |
163,000
ft2
|
Annual Production | 7,900
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,383,404 | 17,634,750 |
kWh
|
$0.14 |
Electricity Demand | $99,138 | 30,785 |
kW-mo/yr
|
$3.22 |
Electricity Fees | $(-77.0) | - |
|
- |
Natural Gas | $1,397,304 | 163,046 |
MMBtu
|
$8.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,908,752 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $66,725 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3416: Use combined cycle gas turbine generator sets with waste heat boilers connected to turbine exhaust | $1,595,248 | $5,445,000 |
$2,103,177
15,579,089
kWh
|
$342,740 |
$(-539,087.0)
-
MMBtu
|
- | $(-311,582.0) | - | |
02 | 2.2625: Chill water to the highest temperature possible | $112,215 | $1,000 |
$112,215
831,223
kWh
|
- | - | - | - | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $71,309 | $500,000 |
$71,309
528,214
kWh
|
- | - | - | - | - | |
04 | 2.2121: Increase amount of condensate returned | $62,104 | $250,000 | - | - |
$33,337
-
MMBtu
|
$20,329
-
Tgal
|
- |
$8,438
-
Tgal
|
|
05 | 3.4116: Meter recycled water (to reduce sewer charges) | $34,769 | $3,000 | - | - | - |
$34,769
-
Tgal
|
- | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $25,043 | $13,895 |
$25,043
185,507
kWh
|
- | - | - | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,913 | $4,940 |
$6,913
51,208
kWh
|
- | - | - | - | - | |
08 | 2.4134: Replace electric motor with fossil fuel engine | $1,151 | $500 |
$1,151
8,528
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $1,908,752 | $6,218,335 |
$2,319,808
17,183,769
kWh
|
$342,740 |
$(-505,750.0)
-
MMBtu
|
$55,098
-
Tgal
|
$(-311,582.0) |
$8,438
-
Tgal
|
||
TOTAL IMPLEMENTED | $66,725 | $21,835 |
$31,956
236,715
kWh
|
- | - |
$34,769
-
Tgal
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs