Assessment Year | 2014 |
---|---|
Principal Product | WWT Plant |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $1 M to 5M |
# of Employees | 10 |
Plant Area |
75,000
ft2
|
Annual Production | 1,058,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $93,463 | 728,560 |
kWh
|
$0.13 |
Natural Gas | $13,898 | 1,352 |
MMBtu
|
$10.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,117 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,813 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3322: Use existing dam to generate electricity | $17,926 | $250,000 |
$17,926
139,722
kWh
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,649 | $3,000 |
$7,649
59,619
kWh
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,813 | $5,000 |
$4,813
37,514
kWh
|
|
04 | 2.4131: Size electric motors for peak operating efficiency | $729 | $300 |
$729
5,682
kWh
|
|
TOTAL RECOMMENDED | $31,117 | $258,300 |
$31,117
242,537
kWh
|
||
TOTAL IMPLEMENTED | $4,813 | $5,000 |
$4,813
37,514
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs