| Assessment Year | 2013 |
|---|---|
| Principal Product | Thermal imaging lens elements and lens assemblies |
| NAICS | 333314: Optical Instrument and Lens Manufacturing |
| SIC | 3827: Optical Instruments and Lenses |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
32,727
ft2
|
| Annual Production | 225,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $170,799 | 1,770,837 |
kWh
|
$0.096 |
| Other Energy | $24,313 | 1,875 |
MMBtu
|
$12.97 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,914 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,968 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $4,752 | $30,000 |
$4,752
49,239
kWh
|
- | |
| 02 | 2.7314: Reduce ventilation air | $3,194 | $7,450 |
$1,741
18,042
kWh
|
$1,453
-
MMBtu
|
|
| 03 | 2.6218: Turn off equipment when not in use | $3,140 | $400 |
$3,140
32,544
kWh
|
- | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,828 | $3,200 |
$1,828
18,938
kWh
|
- | |
| TOTAL RECOMMENDED | $12,914 | $41,050 |
$11,461
118,763
kWh
|
$1,453
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,968 | $3,600 |
$4,968
51,482
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs