Assessment Year | 2010 |
---|---|
Principal Product | Silicon Carbide |
NAICS | 333314: Optical Instrument and Lens Manufacturing |
SIC | 3827: Optical Instruments and Lenses |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
80,000
ft2
|
Annual Production | 12
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $420,845 | 3,399,800 |
kWh
|
$0.12 |
Electricity Demand | $56,349 | 13,913 |
kW-mo/yr
|
$4.05 |
Electricity Fees | $26,140 | - |
|
- |
Natural Gas | $3,831 | 227 |
MMBtu
|
$16.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $103,955 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $87,113 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,403 | $9,546 |
$5,403
43,646
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,241 | - |
$2,241
18,108
kWh
|
- | |
03 | 2.6218: Turn off equipment when not in use | $58,587 | - |
$58,587
473,240
kWh
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,601 | $19,240 |
$13,973
112,871
kWh
|
$628
-
kW-mo/yr
|
|
05 | 2.2625: Chill water to the highest temperature possible | $23,123 | - |
$23,123
186,775
kWh
|
- | |
TOTAL RECOMMENDED | $103,955 | $28,786 |
$103,327
834,640
kWh
|
$628
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $87,113 | $9,546 |
$87,113
703,661
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs