Assessment Year 2010
Principal Product Polysirene resin
NAICS 325211: Plastics Material and Resin Manufacturing
SIC 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers
Sales Range $100
M
to 500
M
# of Employees 25
Plant Area 61,500
ft2
Annual Production 243,000,000
lb
Production Hrs. Annual 8,760
hrs
Location (State) Connecticut

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,701,542 12,338,955
kWh
Fuel Oil #2 $579,409 36,539
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $115,477 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $95,958

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4322: Use or replace with energy efficient substitutes $28,838 $12,936 $28,838
209,119
kWh
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $24,790 $30,125 $24,790
179,764
kWh
03 2.2614: Use cooling tower or economizer to replace chiller cooling $16,037 $34,430 $16,037
116,297
kWh
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $12,502 $13,850 $12,502
90,666
kWh
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $11,587 $13,850 $11,587
84,027
kWh
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,142 $18,500 $8,142
59,043
kWh
07 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,702 $3,170 $3,702
26,852
kWh
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,482 $3,175 $3,482
25,250
kWh
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,225 $4,295 $3,225
23,391
kWh
10 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,172 $5,170 $3,172
23,002
kWh
TOTAL RECOMMENDED $115,477 $139,501 $115,477
837,411
kWh
TOTAL IMPLEMENTED $95,958 $101,896 $95,958
695,864
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs