Assessment Year 2009
Principal Product Desiccant Dehumidification Air Handlers
NAICS 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment
Sales Range $50
M
to 100
M
# of Employees 459
Plant Area 130,000
ft2
Annual Production 550
pieces
Production Hrs. Annual 4,420
hrs
Location (State) Massachusetts

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $394,802 3,216,102
kWh
Electricity Fees $1,213 -
Natural Gas $131,023 9,722
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $75,021 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $66,924

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2444: Use hot process fluids to preheat incoming process fluids $34,492 $160,000 $31,802
258,978
kWh
$2,690
-
MMBtu
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $12,900 - $12,900
105,000
kWh
-
03 2.7314: Reduce ventilation air $11,580 $25,000 - $11,580
-
MMBtu
04 2.4323: Use optimum size and capacity equipment $8,097 $37,500 - $8,097
-
MMBtu
05 2.7314: Reduce ventilation air $6,015 $2,600 $2,680
21,820
kWh
$3,335
-
MMBtu
06 2.7221: Lower temperature during the winter season and vice-versa $1,937 - - $1,937
-
MMBtu
TOTAL RECOMMENDED $75,021 $225,100 $47,382
385,798
kWh
$27,639
-
MMBtu
TOTAL IMPLEMENTED $66,924 $187,600 $47,382
385,798
kWh
$19,542
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings