Assessment Year | 2008 |
---|---|
Principal Product | Steel products |
NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
46,782
ft2
|
Annual Production | 109,000,000
pieces
|
Production Hrs. Annual | 5,382
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $184,471 | 1,161,040 |
kWh
|
$0.16 |
Electricity Demand | $75,119 | 7,372 |
kW-mo/yr
|
$10.19 |
LPG | $67,771 | 3,276 |
MMBtu
|
$20.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,941 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,375 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $10,924 | $18,000 | - | - |
$10,924
-
MMBtu
|
|
02 | 2.7221: Lower temperature during the winter season and vice-versa | $4,555 | $2,800 |
$4,555
41,000
kWh
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,591 | $4,000 |
$2,153
19,375
kWh
|
$438
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $566 | $2,285 |
$566
5,100
kWh
|
- | - | |
05 | 2.2511: Insulate bare equipment | $305 | $290 |
$305
2,748
kWh
|
- | - | |
TOTAL RECOMMENDED | $18,941 | $27,375 |
$7,579
68,223
kWh
|
$438
-
kW-mo/yr
|
$10,924
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,375 | $25,090 |
$7,013
63,123
kWh
|
$438
-
kW-mo/yr
|
$10,924
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs