Assessment Year | 2005 |
---|---|
Principal Product | Decorated bags and business accessories |
NAICS | 314910: Textile Bag and Canvas Mills |
SIC | 2393: Textile Bags |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
145,000
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $267,573 | 3,104,000 |
kWh
|
$0.086 |
Electricity Demand | $34,165 | 7,270 |
kW-mo/yr
|
$4.70 |
Electricity Fees | $5,356 | - |
|
- |
Natural Gas | $113,115 | 11,818 |
MMBtu
|
$9.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,758 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,074 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $9,175 | $6,831 |
$(-1,236.0)
(-14,560)
kWh
|
$(-101.0)
-
kW-mo/yr
|
$10,512
-
MMBtu
|
- | |
02 | 2.2212: Use minimum safe oven ventilation | $8,663 | $10,750 | - | - |
$8,663
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,371 | $34,720 |
$6,052
71,285
kWh
|
$922
-
kW-mo/yr
|
- | $397 | |
04 | 2.7224: Reduce space conditioning during non-working hours | $5,798 | $1,375 | - | - |
$5,798
-
MMBtu
|
- | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,905 | - |
$1,905
22,440
kWh
|
- | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,479 | $825 |
$1,479
17,421
kWh
|
- | - | - | |
07 | 2.6212: Turn off equipment during breaks, reduce operating time | $611 | - |
$551
6,500
kWh
|
- |
$60
-
MMBtu
|
- | |
08 | 2.2531: Re-size charging openings or add movable cover or door | $444 | - |
$166
1,953
kWh
|
- |
$278
-
MMBtu
|
- | |
09 | 2.6212: Turn off equipment during breaks, reduce operating time | $312 | - |
$312
3,680
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $35,758 | $54,501 |
$9,229
108,719
kWh
|
$821
-
kW-mo/yr
|
$25,311
-
MMBtu
|
$397 | ||
TOTAL IMPLEMENTED | $15,074 | $36,095 |
$7,957
93,725
kWh
|
$922
-
kW-mo/yr
|
$5,798
-
MMBtu
|
$397 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs