Assessment Year | 2004 |
---|---|
Principal Product | Paper products |
NAICS | 322121: Paper (except Newsprint) Mills |
SIC | 2621: Paper Mills |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
104,500
ft2
|
Annual Production | 30,600
ton
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | New Hampshire |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,134,119 | 16,596,400 |
kWh
|
$0.068 |
Electricity Demand | $315,733 | 31,858 |
kW-mo/yr
|
$9.91 |
Electricity Fees | $5,376 | - |
|
- |
Fuel Oil #6 | $1,142,152 | 175,792 |
MMBtu
|
$6.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $469,096 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $301,681 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $148,951 | $35,885 | - | - |
$150,951
-
MMBtu
|
$(-2,000.0) | |
02 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $113,441 | $191,180 |
$227,585
2,891,809
kWh
|
$8,822
-
kW-mo/yr
|
$(-111,399.0)
-
MMBtu
|
$(-11,567.0) | |
03 | 2.2163: Use minimum steam operating pressure | $75,183 | $1,350 | - | - |
$75,183
-
MMBtu
|
- | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $69,926 | $70,000 | - | - |
$69,926
-
MMBtu
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $33,400 | $20,000 | - | - |
$33,400
-
MMBtu
|
- | |
06 | 2.2437: Recover waste heat from equipment | $22,306 | $16,750 | - | - |
$22,306
-
MMBtu
|
- | |
07 | 2.2511: Insulate bare equipment | $5,889 | $3,076 | - | - |
$5,889
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $469,096 | $338,241 |
$227,585
2,891,809
kWh
|
$8,822
-
kW-mo/yr
|
$246,256
-
MMBtu
|
$(-13,567.0) | ||
TOTAL IMPLEMENTED | $301,681 | $250,141 |
$227,585
2,891,809
kWh
|
$8,822
-
kW-mo/yr
|
$78,841
-
MMBtu
|
$(-13,567.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs