Assessment Year 2003
Principal Product PET containers
NAICS 326160: Plastics Bottle Manufacturing
SIC 3085: Plastics Bottles
Sales Range $50
M
to 100
M
# of Employees 26
Plant Area 215,000
ft2
Annual Production 808,000,000
pieces
Production Hrs. Annual 8,712
hrs
Location (State) New Hampshire

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,904,613 26,085,221
kWh
Electricity Demand $310,166 44,726
kW-mo/yr
Electricity Fees $12,064 -
Natural Gas $17,044 2,028
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $81,911 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,979

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Primary Raw Material Savings One-time Revenue or Avoided Cost Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $28,705 $21,900 n/a $24,131
357,500
kWh
$4,574
-
kW-mo/yr
- - - -
02 2.2612: Use cooling tower water instead of refrigeration $26,717 $40,000 $26,717
395,800
kWh
- - - - -
03 2.3131: Reschedule plant operations or reduce load to avoid peaks $12,265 - - $8,413
-
kW-mo/yr
- $3,120 - $732
04 2.2623: Minimize condenser cooling water temperature $5,292 - $5,292
78,400
kWh
- - - - -
05 2.3132: Recharge batteries on during off-peak demand periods $3,953 $12,400 - $3,250
-
kW-mo/yr
- - $703 -
06 2.7243: Improve air circulation with destratification fans / other methods $3,571 $12,104 $(-1,067.0)
(-15,800)
kWh
$(-132.0)
-
kW-mo/yr
$4,770
-
MMBtu
- - -
07 2.7224: Reduce space conditioning during non-working hours $1,408 $527 $470
7,200
kWh
- $938
-
MMBtu
- - -
TOTAL RECOMMENDED $81,911 $86,931 $55,543
823,100
kWh
$16,105
-
kW-mo/yr
$5,708
-
MMBtu
$3,120 $703 $732
TOTAL IMPLEMENTED $4,979 $12,631 $(-597.0)
(-8,600)
kWh
$(-132.0)
-
kW-mo/yr
$5,708
-
MMBtu
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Primary Raw Material Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs