Assessment Year 2003
Principal Product Hardwood furniture
NAICS 337127: Institutional Furniture Manufacturing
SIC 2531: Public Building and Related Furniture
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 140,200
ft2
Annual Production 3,800
thousand feet
Production Hrs. Annual 4,335
hrs
Location (State) New Hampshire

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $265,244 3,516,335
kWh
Electricity Fees $14,300 -
Fuel Oil #2 $8,642 1,318
MMBtu
Wood $63,257 27,833
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $166,806 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,132

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Fuel Oil #2 Savings Wood Savings
01 2.3321: Use steam pressure reduction to generate power $132,710 $407,000 n/a $234,477
2,879,329
kWh
$52,819
-
kW-mo/yr
- $(-148,257.0)
-
MMBtu
$(-6,329.0)
-
MMBtu
02 2.2437: Recover waste heat from equipment $15,152 $66,000 n/a - - - - $15,152
-
MMBtu
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $6,301 $13,950 n/a $6,301
87,451
kWh
- - - -
04 2.2414: Use waste heat from hot flue gases to preheat $7,609 $30,000 - - - - $7,609
-
MMBtu
05 2.8123: Pay utility bills on time $2,902 $345 - - $2,902 - -
06 2.2136: Install / repair insulation on steam lines $1,837 $827 - - - - $1,837
-
MMBtu
07 2.2135: Repair and eliminate steam leaks $295 $600 - - - - $295
-
MMBtu
TOTAL RECOMMENDED $166,806 $518,722 $240,778
2,966,780
kWh
$52,819
-
kW-mo/yr
$2,902 $(-148,257.0)
-
MMBtu
$18,564
-
MMBtu
TOTAL IMPLEMENTED $2,132 $1,427 - - - - $2,132
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Fuel Oil #2 Savings Wood Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs