| Assessment Year | 2002 |
|---|---|
| Principal Product | Metal fabrication |
| NAICS |
n/a
|
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 65 |
| Plant Area |
27,000
ft2
|
| Annual Production | 5,000
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $52,987 | 678,528 |
kWh
|
$0.078 |
| Natural Gas | $33,253 | 3,560 |
MMBtu
|
$9.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,498 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,438 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $8,976 | - | - | - | $8,976 | |
| 02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $4,745 | $4,805 | - |
$4,745
-
MMBtu
|
- | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $3,060 | - | - | - | $3,060 | |
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $717 | - |
$717
9,667
kWh
|
- | - | |
| TOTAL RECOMMENDED | $17,498 | $4,805 |
$717
9,667
kWh
|
$4,745
-
MMBtu
|
$12,036 | ||
| TOTAL IMPLEMENTED | $14,438 | $4,805 |
$717
9,667
kWh
|
$4,745
-
MMBtu
|
$8,976 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs