| Assessment Year | 2001 |
|---|---|
| Principal Product | Dyeing, Finishing and coating of synthetic and natural fabri |
| NAICS |
n/a
|
| SIC | 2258: Lace and Warp Knit Fabric Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
287,000
ft2
|
| Annual Production | 57,600
thousand feet
|
| Production Hrs. Annual | 5,760
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $371,730 | 8,571,176 |
kWh
|
$0.043 |
| Electricity Demand | $174,982 | 20,350 |
kW-mo/yr
|
$8.60 |
| Electricity Fees | $65,018 | - |
|
- |
| Natural Gas | $717,270 | 124,584 |
MMBtu
|
$5.76 |
| LPG | $45,192 | 4,936 |
MMBtu
|
$9.16 |
| Other Energy | $353,666 | 171,117 |
MMBtu
|
$2.07 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,502,600 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Energy Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 4.114: Add/modify equipment to improve drying process | $496,200 | $950,000 |
$246,200
4,940,600
kWh
|
- |
$250,000
-
MMBtu
|
- | |
| 02 | 4.114: Add/modify equipment to improve drying process | $432,600 | $425,000 |
$208,000
3,984,000
kWh
|
- |
$224,600
-
MMBtu
|
- | |
| 03 | 2.2444: Use hot process fluids to preheat incoming process fluids | $122,200 | $165,000 | - |
$(-5,500.0)
-
kW-mo/yr
|
$(-15,700.0)
-
MMBtu
|
$143,400
-
MMBtu
|
|
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $155,300 | $44,000 |
$12,300
236,050
kWh
|
- |
$143,000
-
MMBtu
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $112,000 | $135,000 | - | - |
$112,000
-
MMBtu
|
- | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $72,000 | $100,000 |
$5,000
120,000
kWh
|
- |
$67,000
-
MMBtu
|
- | |
| 07 | 2.2414: Use waste heat from hot flue gases to preheat | $61,000 | $23,000 | - | - | - |
$61,000
-
MMBtu
|
|
| 08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $50,300 | $13,000 | - | - | - |
$50,300
-
MMBtu
|
|
| 09 | 2.4221: Install compressor air intakes in coolest locations | $1,000 | $850 |
$1,000
11,700
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $1,502,600 | $1,855,850 |
$472,500
9,292,350
kWh
|
$(-5,500.0)
-
kW-mo/yr
|
$780,900
-
MMBtu
|
$254,700
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Energy Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs