| Assessment Year | 2000 |
|---|---|
| Principal Product | High performance Plastics |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
100,000
ft2
|
| Annual Production | 2,000,000
lb
|
| Production Hrs. Annual | 6,656
hrs
|
| Location (State) | Rhode Island |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $437,569 | 6,972,743 |
kWh
|
$0.063 |
| Electricity Demand | $50,791 | 17,947 |
kW-mo/yr
|
$2.83 |
| Electricity Fees | $2,837 | - |
|
- |
| Natural Gas | $119,468 | 25,173 |
MMBtu
|
$4.75 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $171,763 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $93,496 | $240,000 |
$112,979
1,847,890
kWh
|
$12,327
-
kW-mo/yr
|
$(-31,810.0)
-
MMBtu
|
|
| 02 | 2.2212: Use minimum safe oven ventilation | $33,134 | $16,250 | - |
$33,134
-
kW-mo/yr
|
- | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $24,310 | $50,000 | - | - |
$24,310
-
MMBtu
|
|
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $16,701 | $16,000 |
$16,701
273,154
kWh
|
- | - | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,122 | $8,000 |
$4,122
67,409
kWh
|
- | - | |
| TOTAL RECOMMENDED | $171,763 | $330,250 |
$133,802
2,188,453
kWh
|
$45,461
-
kW-mo/yr
|
$(-7,500.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs