Assessment Year | 1998 |
---|---|
Principal Product | Diaphragms for pressure regulators |
NAICS |
n/a
|
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 66 |
Plant Area |
28,940
ft2
|
Annual Production | 500,000
lb
|
Production Hrs. Annual | 4,446
hrs
|
Location (State) | New Hampshire |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $92,740 | 813,306 |
kWh
|
$0.11 |
Electricity Demand | $18,053 | 2,244 |
kW-mo/yr
|
$8.05 |
Natural Gas | $24,635 | 3,934 |
MMBtu
|
$6.26 |
Fuel Oil #2 | $12,291 | 2,466 |
MMBtu
|
$4.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,724 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,375 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.424: Improve space comfort conditioning | $14,812 | $19,107 |
$(-322.0)
(-3,517)
kWh
|
$(-72.0)
-
kW-mo/yr
|
- | - | $15,206 | |
02 | 2.6218: Turn off equipment when not in use | $1,695 | $5,302 |
$1,582
17,292
kWh
|
$113
-
kW-mo/yr
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $268 | - |
$268
2,931
kWh
|
- | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $412 | $60 |
$412
4,396
kWh
|
- | - | - | - | |
05 | 2.2136: Install / repair insulation on steam lines | $269 | $66 | - | - |
$185
-
MMBtu
|
$84
-
MMBtu
|
- | |
06 | 2.2623: Minimize condenser cooling water temperature | $268 | $130 |
$268
2,931
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $17,724 | $24,665 |
$2,208
24,033
kWh
|
$41
-
kW-mo/yr
|
$185
-
MMBtu
|
$84
-
MMBtu
|
$15,206 | ||
TOTAL IMPLEMENTED | $2,375 | $5,362 |
$2,262
24,619
kWh
|
$113
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs