Assessment Year | 1998 |
---|---|
Principal Product | Narrow Fabrics and Other Smallwears Mills |
NAICS |
n/a
|
SIC | 2241: Narrow Fabric and Other Smallware Mills: Cotton, Wool, Silk, and Manmade Fiber |
Sales Range | $10 M to 50M |
# of Employees | 383 |
Plant Area |
276,000
ft2
|
Annual Production | 8,000
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Rhode Island |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $458,884 | 6,201,934 |
kWh
|
$0.074 |
Electricity Demand | $85,364 | 6,680 |
kW-mo/yr
|
$12.78 |
Fuel Oil #2 | $58,804 | 10,944 |
MMBtu
|
$5.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $36,342 | $53,316 | n/a |
$36,342
487,984
kWh
|
- |
02 | 2.7124: Make a practice of turning off lights when not needed | $4,782 | $800 | n/a |
$4,782
63,306
kWh
|
- |
03 | 2.2623: Minimize condenser cooling water temperature | $2,015 | $2,000 | n/a |
$2,015
26,671
kWh
|
- |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $572 | $1,000 | n/a |
$443
5,862
kWh
|
$129
-
MMBtu
|
TOTAL RECOMMENDED | $43,711 | $57,116 |
$43,582
583,823
kWh
|
$129
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs