Assessment Year | 1996 |
---|---|
Principal Product | Small Firearms |
NAICS |
n/a
|
SIC | 3484: Small Arms |
Sales Range | $1 M to 5M |
# of Employees | 234 |
Plant Area |
168,000
ft2
|
Annual Production | 230,000
pieces
|
Production Hrs. Annual | 5,100
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $231,718 | 2,279,601 |
kWh
|
$0.10 |
Electricity Demand | $96,934 | 10,063 |
kW-mo/yr
|
$9.63 |
Natural Gas | $81,367 | 17,659 |
MMBtu
|
$4.61 |
Fuel Oil #2 | $25,315 | 5,810 |
MMBtu
|
$4.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,515 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $36,015 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.3131: Use evaporation to concentrate material | $24,817 | $16,000 | - | - |
$24,817
-
gal
|
- | |
02 | 3.3112: Utilize oxidation/reduction for neutralization | $18,500 | $3,200 | - | - | - |
$18,500
-
gal
|
|
03 | 2.7314: Reduce ventilation air | $1,830 | $1,150 |
$1,830
74,443
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,918 | $13,680 |
$6,572
63,892
kWh
|
$2,346
-
kW-mo/yr
|
- | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $450 | $516 |
$450
6,741
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $54,515 | $34,546 |
$8,852
145,076
kWh
|
$2,346
-
kW-mo/yr
|
$24,817
-
gal
|
$18,500
-
gal
|
||
TOTAL IMPLEMENTED | $36,015 | $31,346 |
$8,852
145,076
kWh
|
$2,346
-
kW-mo/yr
|
$24,817
-
gal
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs