Assessment Year | 1995 |
---|---|
Principal Product | polyethylene film |
NAICS |
n/a
|
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
300,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,750,147 | 38,640,094 |
kWh
|
$0.071 |
Natural Gas | $606,628 | 86,603 |
MMBtu
|
$7.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $263,701 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $753 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8211: Consolidate freight shipments and/or deliveries | $216,508 | - | - | - | $216,508 | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $23,739 | $37,200 |
$23,739
333,529
kWh
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $21,840 | $3,800 | - |
$21,840
-
MMBtu
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $861 | - |
$861
12,016
kWh
|
- | - | |
05 | 2.7221: Lower temperature during the winter season and vice-versa | $753 | $1,930 | - |
$753
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $263,701 | $42,930 |
$24,600
345,545
kWh
|
$22,593
-
MMBtu
|
$216,508 | ||
TOTAL IMPLEMENTED | $753 | $1,930 | - |
$753
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs