Assessment Year | 1995 |
---|---|
Principal Product | Wire Mesh |
NAICS |
n/a
|
SIC | 3496: Miscellaneous Fabricated Wire Products |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
162,000
ft2
|
Annual Production | 8,000
ton
|
Production Hrs. Annual | 8,184
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $147,845 | 1,148,007 |
kWh
|
$0.13 |
Natural Gas | $355,528 | 65,113 |
MMBtu
|
$5.46 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,136 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,018 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3192: Use fossil fuel powered generator during peak demand periods | $22,525 | $60,000 |
$22,525
-
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,118 | $3,888 |
$2,118
20,516
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,493 | $23,880 |
$5,493
83,236
kWh
|
|
TOTAL RECOMMENDED | $30,136 | $87,768 |
$30,136
103,752
kWh
|
||
TOTAL IMPLEMENTED | $28,018 | $83,880 |
$28,018
83,236
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs