| Assessment Year | 1994 |
|---|---|
| Principal Product | silicon rubber; pressure-sensitive tape |
| NAICS |
n/a
|
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
148,000
ft2
|
| Annual Production | 4,000,000
thousand feet
|
| Production Hrs. Annual | 4,680
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $568,648 | 5,639,508 |
kWh
|
$0.10 |
| Natural Gas | $271,019 | 58,015 |
MMBtu
|
$4.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $114,982 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $107,562 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $87,650 | $18,145 |
$106,173
1,053,048
kWh
|
$(-18,523.0)
-
MMBtu
|
|
| 02 | 2.2113: Repair or replace steam traps | $19,471 | $813 |
$19,471
194,607
kWh
|
- | |
| 03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $7,420 | $7,745 |
$8,658
85,873
kWh
|
$(-1,238.0)
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $441 | $110 |
$441
6,155
kWh
|
- | |
| TOTAL RECOMMENDED | $114,982 | $26,813 |
$134,743
1,339,683
kWh
|
$(-19,761.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $107,562 | $19,068 |
$126,085
1,253,810
kWh
|
$(-18,523.0)
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs