| Assessment Year | 1994 |
|---|---|
| Principal Product | fact booklets |
| NAICS |
n/a
|
| SIC | 2731: Books: Publishing, or Publishing and Printing |
| Sales Range | $10 M to 50M |
| # of Employees | 260 |
| Plant Area |
97,621
ft2
|
| Annual Production | 1,400,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $244,829 | 1,659,437 |
kWh
|
$0.15 |
| Natural Gas | $51,604 | 9,235 |
MMBtu
|
$5.59 |
| Fuel Oil #2 | $9,525 | 2,100 |
MMBtu
|
$4.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $75,924 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,462 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $18,419 | $10,078 | - |
$18,419
-
MMBtu
|
- | - | - | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,978 | $14,015 |
$4,978
55,393
kWh
|
- | - | - | - | |
| 03 | 2.7424: Shade windows from summer sun | $15,022 | $41,394 |
$15,022
588,511
kWh
|
- | - | - | - | |
| 04 | 2.7231: Use radiant heater for spot heating | $1,508 | $5,569 | - | - |
$1,508
-
MMBtu
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $698 | - |
$698
7,913
kWh
|
- | - | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $764 | $180 |
$764
8,499
kWh
|
- | - | - | - | |
| 07 | 3.5121: Recycle waste ink and cleanup solvent | $24,185 | $2,500 | - | - | - |
$24,185
-
gal
|
- | |
| 08 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $10,350 | $385 | - | - | - | - |
$10,350
-
lb
|
|
| TOTAL RECOMMENDED | $75,924 | $74,121 |
$21,462
660,316
kWh
|
$18,419
-
MMBtu
|
$1,508
-
MMBtu
|
$24,185
-
gal
|
$10,350
-
lb
|
||
| TOTAL IMPLEMENTED | $1,462 | $180 |
$1,462
16,412
kWh
|
- | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs