| Assessment Year | 1994 |
|---|---|
| Principal Product | High Pressure Valves |
| NAICS |
n/a
|
| SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 78 |
| Plant Area |
28,500
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $88,182 | 864,596 |
kWh
|
$0.10 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,952 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,672 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,823 | $6,000 |
$2,870
28,136
kWh
|
$(-1,047.0)
-
MMBtu
|
|
| 02 | 2.7221: Lower temperature during the winter season and vice-versa | $3,457 | $1,072 |
$3,457
33,998
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,086 | - |
$1,086
12,309
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $586 | - |
$586
5,862
kWh
|
- | |
| TOTAL RECOMMENDED | $6,952 | $7,072 |
$7,999
80,305
kWh
|
$(-1,047.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,672 | - |
$1,672
18,171
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs