| Assessment Year | 1993 |
|---|---|
| Principal Product | Optical filters and Coat |
| NAICS |
n/a
|
| SIC | 3826: Laboratory Analytical Instruments |
| Sales Range | $1 M to 5M |
| # of Employees | 70 |
| Plant Area |
27,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,368
hrs
|
| Location (State) | Vermont |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,996 | 648,007 |
kWh
|
$0.10 |
| Coal | $2,501 | 348 |
MMBtu
|
$7.19 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,768 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,768 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Coal Savings | Personnel Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.4115: Recover and reuse cooling water | $12,463 | $15,645 |
$(-676.0)
(-6,741)
kWh
|
- | - | - |
$13,139
-
Tgal
|
|
| 02 | 2.1333: Convert combustion equipment to burn oil | $6,283 | $6,250 | - |
$(-1,678.0)
-
MMBtu
|
$2,501
-
MMBtu
|
$5,460 | - | |
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,851 | $1,190 |
$1,851
18,464
kWh
|
- | - | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,146 | $3,034 |
$1,146
11,430
kWh
|
- | - | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,025 | $110 |
$1,025
12,016
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $22,768 | $26,229 |
$3,346
35,169
kWh
|
$(-1,678.0)
-
MMBtu
|
$2,501
-
MMBtu
|
$5,460 |
$13,139
-
Tgal
|
||
| TOTAL IMPLEMENTED | $22,768 | $26,229 |
$3,346
35,169
kWh
|
$(-1,678.0)
-
MMBtu
|
$2,501
-
MMBtu
|
$5,460 |
$13,139
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs