Assessment Year | 1993 |
---|---|
Principal Product | Polyurethane film,sheet |
NAICS |
n/a
|
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 100 |
Plant Area |
50,000
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 6,320
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $324,519 | 3,813,013 |
kWh
|
$0.085 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 3.4115: Recover and reuse cooling water | $27,923 | $65,033 |
$27,923
169,988
kWh
|
- | |
02 | 2.7241: Install outside air damper / economizer on hvac unit | $4,788 | $6,000 |
$4,788
56,272
kWh
|
- | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $7,611 | $13,957 |
$11,223
131,887
kWh
|
$(-3,612.0)
-
MMBtu
|
|
04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $823 | $97 |
$823
9,672
kWh
|
- | |
05 | 2.3191: Use demand controller or load shedder | $2,138 | - |
$2,138
-
kWh
|
- | |
06 | 2.3191: Use demand controller or load shedder | $1,927 | - |
$1,927
-
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,666 | $30,813 |
$3,666
43,083
kWh
|
- | |
TOTAL RECOMMENDED | $48,876 | $115,900 |
$52,488
410,902
kWh
|
$(-3,612.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs