Assessment Year | 1992 |
---|---|
Principal Product | PLASTIC INJECTION MOLDS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 31 |
Plant Area |
n/a
|
Annual Production | 300,000
lb
|
Production Hrs. Annual | 5,928
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $60,138 | 703,107 |
kWh
|
$0.086 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,798 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,482 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $6,316 | - |
$8,624
100,821
kWh
|
$(-2,308.0)
-
MMBtu
|
|
02 | 2.5194: Redesign process | $4,412 | $1,554 |
$4,412
51,583
kWh
|
- | |
03 | 3.4115: Recover and reuse cooling water | $2,833 | $5,040 |
$2,833
33,118
kWh
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $4,237 | - |
$4,237
49,531
kWh
|
- | |
TOTAL RECOMMENDED | $17,798 | $6,594 |
$20,106
235,053
kWh
|
$(-2,308.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $11,482 | $6,594 |
$11,482
134,232
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs