Assessment Year 1992
Principal Product INVESTMENT CASTINGS
NAICS
n/a
SIC 3324: Steel Investment Foundries
Sales Range $10
M
to 50
M
# of Employees 500
Plant Area
n/a
Annual Production 7,000,000
lb
Production Hrs. Annual 6,120
hrs
Location (State) New Hampshire

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,336,182 18,333,822
kWh
LPG $555,181 109,365
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $101,259 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,244

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings LPG Savings Administrative Changes Savings
01 2.2443: Re-use or recycle hot or cold process exhaust air $31,842 $90,600 $(-8,224.0)
(-113,130)
kWh
$40,066
-
MMBtu
-
02 2.4322: Use or replace with energy efficient substitutes $61,173 $70,000 - $61,173
-
MMBtu
-
03 2.2113: Repair or replace steam traps $2,293 $2 - $3,231
-
MMBtu
$(-938.0)
04 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $5,067 - $983
13,482
kWh
$4,084
-
MMBtu
-
05 2.2121: Increase amount of condensate returned $884 $150 - $884
-
MMBtu
-
TOTAL RECOMMENDED $101,259 $160,752 $(-7,241.0)
(-99,648)
kWh
$109,438
-
MMBtu
$(-938.0)
TOTAL IMPLEMENTED $8,244 $152 $983
13,482
kWh
$8,199
-
MMBtu
$(-938.0)
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs