Assessment Year | 1992 |
---|---|
Principal Product | INVESTMENT CASTINGS |
NAICS |
n/a
|
SIC | 3324: Steel Investment Foundries |
Sales Range | $10 M to 50M |
# of Employees | 500 |
Plant Area |
n/a
|
Annual Production | 7,000,000
lb
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | New Hampshire |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,336,182 | 18,333,822 |
kWh
|
$0.073 |
LPG | $555,181 | 109,365 |
MMBtu
|
$5.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $101,259 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,244 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $31,842 | $90,600 |
$(-8,224.0)
(-113,130)
kWh
|
$40,066
-
MMBtu
|
- | |
02 | 2.4322: Use or replace with energy efficient substitutes | $61,173 | $70,000 | - |
$61,173
-
MMBtu
|
- | |
03 | 2.2113: Repair or replace steam traps | $2,293 | $2 | - |
$3,231
-
MMBtu
|
$(-938.0) | |
04 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $5,067 | - |
$983
13,482
kWh
|
$4,084
-
MMBtu
|
- | |
05 | 2.2121: Increase amount of condensate returned | $884 | $150 | - |
$884
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $101,259 | $160,752 |
$(-7,241.0)
(-99,648)
kWh
|
$109,438
-
MMBtu
|
$(-938.0) | ||
TOTAL IMPLEMENTED | $8,244 | $152 |
$983
13,482
kWh
|
$8,199
-
MMBtu
|
$(-938.0) |