Assessment Year | 1991 |
---|---|
Principal Product | COTTEN,POLY BLEND SHIRTS |
NAICS |
n/a
|
SIC | 2321: Men's and Boys' Shirts, Except Work Shirts |
Sales Range | $5 M to 10M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 2,880,000
pieces
|
Production Hrs. Annual | 2,168
hrs
|
Location (State) | Rhode Island |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $28,162 | 282,532 |
kWh
|
$0.100 |
Natural Gas | $7,665 | 1,202 |
MMBtu
|
$6.38 |
Fuel Oil #4 | $8,792 | 1,656 |
MMBtu
|
$5.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,715 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,715 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #4 Savings |
---|---|---|---|---|---|---|---|
01 | 2.2122: Install / repair insulation on condensate lines | $300 | $136 | - |
$140
-
MMBtu
|
$160
-
MMBtu
|
|
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $191 | $350 | - |
$191
-
MMBtu
|
- | |
03 | 2.2441: Preheat boiler makeup water with waste process heat | $651 | $2,764 | - |
$651
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $136 | $47 |
$136
1,465
kWh
|
- | - | |
05 | 2.1213: Direct warmest air to combustion intake | $151 | $405 | - |
$77
-
MMBtu
|
$74
-
MMBtu
|
|
06 | 2.1333: Convert combustion equipment to burn oil | $1,286 | $2,375 | - | - |
$1,286
-
MMBtu
|
|
TOTAL RECOMMENDED | $2,715 | $6,077 |
$136
1,465
kWh
|
$1,059
-
MMBtu
|
$1,520
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,715 | $6,077 |
$136
1,465
kWh
|
$1,059
-
MMBtu
|
$1,520
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #4 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs