Assessment Year | 1990 |
---|---|
Principal Product | VARIOUS GRADES OF PAPER |
NAICS |
n/a
|
SIC | 2621: Paper Mills |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $547,307 | 9,748,828 |
kWh
|
$0.056 |
Fuel Oil #6 | $445,591 | 145,449 |
MMBtu
|
$3.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $73,700 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,019 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #6 Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $29,260 | $96,000 | - |
$29,260
-
MMBtu
|
|
02 | 2.2123: Insulate feedwater tank | $1,053 | $352 | - |
$1,053
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $147 | $118 | - |
$147
-
MMBtu
|
|
04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $19,829 | $22,178 |
$(-2,846.0)
(-50,703)
kWh
|
$22,675
-
MMBtu
|
|
05 | 2.7224: Reduce space conditioning during non-working hours | $2,282 | $200 |
$2,282
40,739
kWh
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,992 | $21,942 |
$17,992
320,633
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,137 | $3,492 |
$3,137
55,979
kWh
|
- | |
TOTAL RECOMMENDED | $73,700 | $144,282 |
$20,565
366,648
kWh
|
$53,135
-
MMBtu
|
||
TOTAL IMPLEMENTED | $24,019 | $26,022 |
$291
5,276
kWh
|
$23,728
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #6 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs