| Assessment Year | 1990 |
|---|---|
| Principal Product | GRANULATORS & SHREDDERS |
| NAICS |
n/a
|
| SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 114 |
| Plant Area |
n/a
|
| Annual Production | 1,980,000
lb
|
| Production Hrs. Annual | 2,470
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $96,483 | 1,168,230 |
kWh
|
$0.083 |
| Natural Gas | $26,569 | 4,242 |
MMBtu
|
$6.26 |
| Fuel Oil #2 | $8,495 | 1,532 |
MMBtu
|
$5.55 |
| Fuel Oil #4 | $10,862 | 2,362 |
MMBtu
|
$4.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,338 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,501 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #4 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2113: Repair or replace steam traps | $1,017 | $1,992 | - | - |
$3,168
-
MMBtu
|
$(-2,151.0) | |
| 02 | 2.3212: Optimize plant power factor | $4,754 | $9,230 |
$4,754
5,862
kWh
|
- | - | - | |
| 03 | 2.2437: Recover waste heat from equipment | $1,162 | $476 |
$1,205
56,565
kWh
|
$(-43.0)
-
MMBtu
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,066 | $4,648 |
$7,066
85,580
kWh
|
- | - | - | |
| 05 | 2.7229: Air condition only space necessary | $7,339 | $3,720 | - | - |
$7,339
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $21,338 | $20,066 |
$13,025
148,007
kWh
|
$(-43.0)
-
MMBtu
|
$10,507
-
MMBtu
|
$(-2,151.0) | ||
| TOTAL IMPLEMENTED | $8,501 | $4,196 |
$1,205
56,565
kWh
|
$(-43.0)
-
MMBtu
|
$7,339
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs