Assessment Year | 1990 |
---|---|
Principal Product | MOLDED RUBBER PRODUCTS |
NAICS |
n/a
|
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 95 |
Plant Area |
n/a
|
Annual Production | 1,200,000
lb
|
Production Hrs. Annual | 6,540
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $291,520 | 3,610,786 |
kWh
|
$0.081 |
Natural Gas | $70,150 | 22,288 |
MMBtu
|
$3.15 |
Fuel Oil #4 | $34,366 | 6,396 |
MMBtu
|
$5.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,171 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,224 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1221: Replace obsolete burners with more efficient ones | $13,039 | $43,000 | - |
$13,039
-
MMBtu
|
- | |
02 | 3.4115: Recover and reuse cooling water | $10,670 | $8,250 |
$(-2,468.0)
(-33,998)
kWh
|
- | $13,138 | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $11,908 | $2,350 |
$14,532
179,953
kWh
|
$(-2,624.0)
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $554 | $70 |
$554
6,741
kWh
|
- | - | |
TOTAL RECOMMENDED | $36,171 | $53,670 |
$12,618
152,696
kWh
|
$10,415
-
MMBtu
|
$13,138 | ||
TOTAL IMPLEMENTED | $11,224 | $8,320 |
$(-1,914.0)
(-27,257)
kWh
|
- | $13,138 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs