Assessment Year | 1990 |
---|---|
Principal Product | FORGINGS |
NAICS |
n/a
|
SIC | 3463: Nonferrous Forgings |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
n/a
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 3,283
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $163,783 | 1,877,784 |
kWh
|
$0.087 |
Natural Gas | $87,272 | 16,028 |
MMBtu
|
$5.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,131 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,131 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $499 | $168 |
$499
5,862
kWh
|
- | |
02 | 2.2531: Re-size charging openings or add movable cover or door | $4,911 | $2,000 | - |
$4,911
-
MMBtu
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,721 | $326 |
$792
9,086
kWh
|
$1,929
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,131 | $2,494 |
$1,291
14,948
kWh
|
$6,840
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,131 | $2,494 |
$1,291
14,948
kWh
|
$6,840
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs