Assessment Year | 1988 |
---|---|
Principal Product | WOOD FLAKE BOARD |
NAICS |
n/a
|
SIC | 2493: Reconstituted Wood Products |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
n/a
|
Annual Production | 100,000
thousand feet
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | New Hampshire |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,119,964 | 17,303,928 |
kWh
|
$0.065 |
Fuel Oil #2 | $1,062,076 | 259,280 |
MMBtu
|
$4.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $210,904 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Wood Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $21,434 | $11,653 |
$21,434
86,753
kWh
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $6,294 | $6,575 |
$(-946.0)
(-14,654)
kWh
|
$7,240
-
MMBtu
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $8,620 | $10,167 |
$8,620
82,943
kWh
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $17,034 | - |
$17,034
263,775
kWh
|
- | - | |
05 | 2.7291: Reschedule and rearrange multiple-source heating systems | $72,100 | $35,000 | - |
$104,033
-
MMBtu
|
$(-31,933.0)
-
MMBtu
|
|
06 | 2.2444: Use hot process fluids to preheat incoming process fluids | $85,422 | $26,275 |
$(-1,437.0)
(-22,274)
kWh
|
$86,859
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $210,904 | $89,670 |
$44,705
396,543
kWh
|
$198,132
-
MMBtu
|
$(-31,933.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Wood Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs