| Assessment Year | 1986 |
|---|---|
| Principal Product | ELECTROPLATING |
| NAICS |
n/a
|
| SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 5,772
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $76,934 | 884,525 |
kWh
|
$0.087 |
| Natural Gas | $74,668 | 11,118 |
MMBtu
|
$6.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,376 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $25,796 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $377 | $75 |
$377
4,396
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,235 | $248 |
$2,235
25,791
kWh
|
- | - | |
| 03 | 2.2113: Repair or replace steam traps | $14,400 | $650 | - |
$17,200
-
MMBtu
|
$(-2,800.0) | |
| 04 | 2.2514: Cover open tanks | $12,580 | $1,239 | - |
$12,580
-
MMBtu
|
- | |
| 05 | 2.3312: Install efficient rectifiers | $8,784 | $40,000 |
$8,784
101,114
kWh
|
- | - | |
| TOTAL RECOMMENDED | $38,376 | $42,212 |
$11,396
131,301
kWh
|
$29,780
-
MMBtu
|
$(-2,800.0) | ||
| TOTAL IMPLEMENTED | $25,796 | $40,973 |
$11,396
131,301
kWh
|
$17,200
-
MMBtu
|
$(-2,800.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs