| Assessment Year | 1985 |
|---|---|
| Principal Product | INJECTION-MOLDED PLASTIC |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
n/a
|
| Annual Production | 2,500,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $56,439 | 792,497 |
kWh
|
$0.071 |
| Natural Gas | $1,847 | 250 |
MMBtu
|
$7.39 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,386 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $530 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $738 | $1,650 |
$738
10,258
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $530 | $74 |
$530
7,327
kWh
|
- | |
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,418 | $168 |
$3,418
48,066
kWh
|
- | |
| 04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $924 | $1,350 | - |
$924
-
MMBtu
|
|
| 05 | 2.3212: Optimize plant power factor | $776 | $1,875 |
$776
-
kWh
|
- | |
| TOTAL RECOMMENDED | $6,386 | $5,117 |
$5,462
65,651
kWh
|
$924
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $530 | $74 |
$530
7,327
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs